Free models · CC0
Buildings
Every building below is a self-contained .glb under 5 MB, released under CC0 1.0 so it can be used and modified in commercial projects without attribution.
Load one straight from its CDN URL with a plain GLTFLoader, or take a whole buildings set from the packs.
500 free GLB models
Observation gantry (UFO Crash Site and Recovery Facility)
A 7 m elevated observation walkway at 3.4 m: six columns on pads with knee braces, a grated deck, handrails with toe boards on both sides and the end, a nine-tread stair flight with its own rails and a deck light.
Overhead crane rail (UFO Crash Site and Recovery Facility)
A 12.4 m span overhead travelling crane 7.2 m to the walkway: four columns on pads with knee braces, two runway beams, a twin girder bridge on end carriages, a trolley node and a hook block node hanging on its ropes, plus a wall pendant station.
Decontamination arch (UFO Crash Site and Recovery Facility)
A 3 m walk-through decontamination arch: an arched shell of real thickness, twenty one spray nozzles on three rings and two side rails, two lamp strips, a grated floor between yellow kerbs and a control box.
Containment cell (UFO Crash Site and Recovery Facility)
A 4.4 by 4 m sealed cell: steel walls with external ribs, roof plant and service risers, a 2.5 m viewing window in pressure frames, a hinged sealed door with a vision port, a grated floor, a ceiling light panel and a lit central plinth. Interior surfaces are modelled.
Twin leaf blast door (UFO Crash Site and Recovery Facility)
A 6.4 by 5 m twin leaf sliding blast door in a concrete portal: ribbed steel leaves on floor tracks and a head beam, two drive units, chevron edge markings, a warning beacon and a control box. Each leaf is a separate node.
Panoramic Lift (Airport Terminal and Ground Operations)
Two floor panoramic passenger lift: a four column glazed shaft with a head deck, a glazed car at the lower landing with a lit ceiling and handrail, centre-opening door leaves on a named pivot and a landing call panel.
Escalator (Airport Terminal and Ground Operations)
Single width escalator rising 3.2 m over a 5.6 m incline: a boxed truss with a saw-tooth step band, comb plates at both landings, glazed balustrades with newel ends and a dark moving handrail.
Travelator Section (Airport Terminal and Ground Operations)
Eight metre level travelator section: a shallow pallet deck with cleat lines and amber comb plates at both ends, glazed balustrades with dark handrails, newel ends and a start-of-run status post.
Retail Unit (Airport Terminal and Ground Operations)
Airside retail unit: a boxed shop with a deep signage fascia over a full-width glazed front, a service counter with a till, and two runs of three-tier gondola shelving stocked with blank cartons.
Cafe Unit (Airport Terminal and Ground Operations)
Concourse cafe counter: an amber service bar with a glazed pastry case, espresso machine and till, a back bar with a three panel menu board and a cup shelf, and two bar stools.
Capsule blast door with locking wheel (Cold War Missile Silo and Command Bunker)
The capsule entry closure: a concrete surround with a stepped steel frame, a raised sill and a hinge column, a slab leaf with eight radial locking dogs, three hinge arms and a viewing port, and a four-spoke locking handwheel on its hub.
Launch control capsule cutaway (Cold War Missile Silo and Command Bunker)
A cutaway of a buried launch control capsule: a 9 m steel pressure shell with internal stiffener rings, an aft bulkhead, a forward door aperture ring, a suspended grating floor on coil isolators, and ceiling cable trays with a ventilation duct.
Personnel access shaft cutaway (Cold War Missile Silo and Command Bunker)
An 8.6 m cutaway personnel shaft: a concrete shaft with a steel liner, two grating landings with handrails, a caged ladder run, a cable tray, a floor grating at the bottom and a collar with a hinged hatch at grade.
Launch tube cutaway section (Cold War Missile Silo and Command Bunker)
A cutaway section of a hardened launch tube: an 18 m concrete wall 0.52 m thick with a welded steel liner, stiffener rings, three grating work platforms with handrails, a caged ladder, cable raceways, a stepped launch mount and a hazard-banded muzzle seat.
Underground refuge chamber (Underground Mine and Shaft Works)
A six metre steel refuge chamber on skids with a sealed door, a viewing port, external breathing air cylinders, a scrubber cabinet, a roof beacon and an entry step with handrails.
Drainage sump (Underground Mine and Shaft Works)
A concrete drainage sump with an open pit, a removable steel grating over half the opening, a fixed access ladder and a suction pipe with a strainer.
Underground pump station (Underground Mine and Shaft Works)
A dewatering pump station: two horizontal pumps with motors on a concrete plinth, suction manifolds, a delivery header with valves and a control cabinet.
Ventilation airlock door (Underground Mine and Shaft Works)
A concrete bulkhead filling the drift section, with a framed vehicle opening closed by two named door leaves, a personnel door beside it and an airflow warning light.
Mine car tipple (Underground Mine and Shaft Works)
A timber framed tipple with an elevated track deck, a named tipping cradle, a receiving bin and a discharge chute.
Shaft loading pocket (Underground Mine and Shaft Works)
A steel measuring flask on a braced frame with a lower chute, a hydraulic sector gate and a control cabinet, used to load skips at the shaft bottom.
Entrance draught lobby (Bar, Pub and Brewery Taproom)
A 1.5 m timber draught lobby: corner posts and fielded side panels with glazed upper lights, a moulded head both sides, a threshold plate and two glazed swing doors with brass push plates.
Panelled pillar with brass rail (Bar, Pub and Brewery Taproom)
A 2.6 m panelled room pillar: a dark plinth with a moulded base, fielded panels on all four faces, a moulded capital, brass rails on turned brackets across the two side faces and bullnose drink shelves on the other two.
Pub fireplace (Bar, Pub and Brewery Taproom)
A 1.3 m pub fireplace: a stone hearth, a cast surround with fluted jambs and a moulded frieze, a bullnose mantel shelf, tiled cheeks and back, and a barred firebasket with coals.
Tank walkway platform (Bar, Pub and Brewery Taproom)
A 1.8 m steel tank walkway: box-section legs and beams with diagonal braces, an open bar grating deck with kick plates, a handrail with a mid rail on three sides and a five rung access ladder.